Flow Tech Inc.代理  Flow Tech Inc.血管造影劑代理

Prices and Available Colors

Kit

Weight

Color

Price

B

1 lb.

One color

$150

C

2 lbs.

One or two colors

$275

D

1 gal. (8 lbs.)

One to four colors

$950

Kit weight is based upon the combined weight of MV-Compound and MV-Diluent only, ie. a 1lb. kit contains 8 oz. of MV compound and 8 oz. of diluent.

Sufficient MV-Curing Agent is supplied at no charge to cure the contents of the kit.

A one pound kit has a volume of approximay 400 ml.

MICROFIL廬 CP-101 For Cast Corrosion Preparations

Kit

Weight

Color

Price

CP-101

1 lb.

Milky

$140

Kit weight is based upon the weight of MICROFIL廬 CP-101 (16 oz.). Sufficient curing agents are supplied at no charge to cure the contents of the kit.

Curing System

Stannous octoate in combination with ethyl silicate.

Mixing Directions

Cure is accomplished by mixing CP-101 with 5% ethyl silicate and 5% stannous octoate (by weight). Upon addition of curing agents, working time is approximay 45 minutes.

Clearing Procedure

Either alcohol-methyl salicylate or glycerin may be employed.聽See more details.

Corrosion Preparations

Potassium hydroxide may be used in studies where the vessels have a diameter of greater than 100 microns.

Corrosion Clearing Procedure

Cast corrosion can be obtained as follows: After the casting material has been compley hardened, place the perfused organ in 20% potassium hydroxide or sodium hydroxide solution for several days. The cast should then be rinsed several times in water until all the tissue is removed. The casting time depends both on the concentration of the corrosive solution and on the tissue itself. Lung and heart tissue require 5-6 days in potassium hydroxide whereas bone and brain tissue may require 35% potassium hydroxide for up to 10 days.

Advantages

MICROFIL CP-101 will maintain dimensional integrity on storage. There is no diluent in the system.